Location:

Altensteinstr. 23a, Biolabs 114.XX, 115.XX, 027.1


Responsible persons

Elisa Quaas, phone: 63652, mail: eqaas@zedat.fu-berlin.de

Johanna Scholz, phone: 71087, mail: johanna.scholz1@fu-berlin.de

Katharina Achazi, phone: 59145,  katharina.achazi@fu-berlin.de

Stefanie Wedepohl, phone 58721, stefanie.wedepohl@fu-berlin.de


Application/Technical Details

Centrifugation of samples for 1.5ml to 50ml Tubes and well plates


Requirements:

  • All users must gain permission to work in the Biolabs and access to the “Zellbio-users” network drive by attending the Biosafety instructions (--> Katharina Achazi)
  • All users must get an introduction to the device by the responsible person
  • DO NOT use the cell culture centrifuges for longer runs (>10min) → in case you need to centrifuge an extended time (>10min), make sure no one needs them for cell culture during this time. Otherwise use a centrifuge in a chemistry lab
  • DO NOT use the cell culture centrifuges for other than biological samples, NO solvents etc. → For non-biological samples use a centrifuge in a chemistry lab
  • close centrifuge and tube lids during centrifugation
  • balance samples for centrifugation before using a balance and place them so that the rotor is in balance
  • wait after start until centrifuge reaches full speed → if the centrifuge shakes or is noisy stop immediately
  • open centrifuge after use and let lid open, so that no condensed water stay inside and cause corrosion
  • clean centrifuge after every use
  • DO NOT use solvents or other evaporating hazardous substances → use instead a centrifuge in a chemistry lab
  • be cautious with rotors e.g. during cleaning, exchanging and store them safe
  • centrifuges must be cleaned once a month with water and soap and wiped afterwards with 70% ethanol
  • centrifuges need to be tested by an authorized service once a year


Instruction/Manual


Serial No.:

42095369 (Heraeus Megafuge 8R, Takustr. 6, K004)

41696601 (Heraeus Megafuge 8R, Arnimallee 22, E002)

721114110508 (Heraeus Megafuge 8, Arnimallee 22, E004)


FUB Inventory No.:

7200005727 (Heraeus Megafuge 8R, Takustr. 6, K004)

3136385 Charite (Heraeus Megafuge 8R, Arnimallee 22, E002)

72000032270 (Heraeus Megafuge 8, Arnimallee 22, E004)


Safety Operation Instruction (German):

{include} konnte nicht gerendert werden Die eingeschlossene Seite konnte nicht gefunden werden.