Class II, Type A2 Biological Safety Cabinets

Location: Altensteinstr. 23a, rooms 114.5, 114.6, 114.7, 115,5, 115.6, 115.7, 027.1 (S2 Biolabs)

Responsible persons & booking:

Cell culture (primary cells) 114.5

Virus lab 114.6 → get special virus lab  intro by lab responsible person before use and follow S2/RG2 Pathogen Lab Rules

Cell culture 114.7

Cell culture 115

Cell culture 115.5

Bacterial lab 115.6 → get special bacteria lab intro by lab responsible person before use and follow S2/RG2 Pathogen Lab Rules

Detailed information and protocols how to use OpenIris you find here.

Requirements:

  • Gain permission to work in the Biolabs by follwoing the How-to-Start procedure.
  • Get access to the BCP-storage network drive suprafab-analytics to save measuremnt data.
  • Book the device using OpenIRIS (protocls see here).
  • Get an introduction to the device by the responsible person (see above).
  • DO NOT use solvents or other evaporating hazardous substances or gases inside the biosafety cabinet as they are no fume hoods and the HEPA-filtered air is circulating back in the room
  • DO NOT work with bacteria or viruses in the cell culture benches → for handling bacteria use only benches in 115.6
  • Biosafety cabinets must be cleaned once a month with water and soap and wiped afterwards with desinfectant acccotding to the hygiene guide
  • Biosafety cabinets need to be tested by an authorized service once a year

Application/Technical Details

A biosafety cabinet is used to handle cells, micro organisms, bio agents or samples a. Exhaust air and makeup air is HEPA-filtered, removing harmful bacteria and viruses:

→ Protection of the laboratory worker and the surrounding environment outside from pathogens

→ Maintain the sterility of materials inside e.g. cell cultures

Instruction/Manual

https://en.wikipedia.org/wiki/Biosafety_cabinet


Serial No.:

42105904 (Herasafe KS12, Takustr. 6, K004)

42105903 (Herasafe KS12, Takustr. 6, K004)

42568740 (Herasafe 2030i, Arnimallee 22, E002)

42568741 (Herasafe 2030i, Arnimallee 22, E002)

42568742 (Herasafe 2030i, Arnimallee 22, E004)

42021699 (Herasafe S2020, Arnimallee 22, E027)


FUB Inventory No.:

8700020104 (Herasafe KS12, Takustr. 6, K004)

8700020105 (Herasafe KS12, Takustr. 6, K004)

N.N. (Herasafe 2030i, Arnimallee 22, E002)

N.N. (Herasafe 2030i, Arnimallee 22, E002)

N.N. (Herasafe 2030i, Arnimallee 22, E004)

8700017331 (Herasafe S2020, Arnimallee 22, E027)


Safety Operation Instruction (German):