Sie zeigen eine alte Version dieser Seite an. Zeigen Sie die aktuelle Version an.

Unterschiede anzeigen Seitenhistorie anzeigen

« Vorherige Version anzeigen Version 16 Nächste Version anzeigen »

Class II, Type A2 Biological Safety Cabinets

Location:

Altensteinstr. 23a, rooms 114.5, 114.6, 114.7, 115,5, 115.6, 115.7, 027.1


Responsible persons & booking:

(primary) cell culture lab 114.5

virus lab 114.6

cell culture lab 114.7

cell culture lab 115

cell culture lab 115.5

bacterial lab 115.6

Detailed information and protocols how to use OpenIris you find here.


Application/Technical Details

A biosafety cabinet is used to handle cells, micro organisms, bio agents or samples a. Exhaust air and makeup air is HEPA-filtered, removing harmful bacteria and viruses:

→ Protection of the laboratory worker and the surrounding environment outside from pathogens

→ Maintain the sterility of materials inside e.g. cell cultures


Requirements:

  • All users must gain permission to work in the Biolabs and access to the “Zellbio-users” network drive by attending the Biosafety instructions (--> Katharina Achazi)
  • All users must get an introduction to the device by the responsible person (see OpenIRIS)
  • Booking via OpenIRIS (protocls see here)
  • DO NOT use solvents or other evaporating hazardous substances or gases inside the biosafety cabinet as they are no fume hoods and the HEPA-filtered air is circulating back in the room
  • DO NOT work with bacteria or viruses in the cell culture benches → for handling bacteria use only benches in 115.6
  • Biosafety cabinets must be cleaned once a month with water and soap and wiped afterwards with desinfectant acccotding to the hygiene guide
  • Biosafety cabinets need to be tested by an authorized service once a year


Instruction/Manual

https://en.wikipedia.org/wiki/Biosafety_cabinet


Serial No.:

42105904 (Herasafe KS12, Takustr. 6, K004)

42105903 (Herasafe KS12, Takustr. 6, K004)

42568740 (Herasafe 2030i, Arnimallee 22, E002)

42568741 (Herasafe 2030i, Arnimallee 22, E002)

42568742 (Herasafe 2030i, Arnimallee 22, E004)

42021699 (Herasafe S2020, Arnimallee 22, E027)


FUB Inventory No.:

8700020104 (Herasafe KS12, Takustr. 6, K004)

8700020105 (Herasafe KS12, Takustr. 6, K004)

N.N. (Herasafe 2030i, Arnimallee 22, E002)

N.N. (Herasafe 2030i, Arnimallee 22, E002)

N.N. (Herasafe 2030i, Arnimallee 22, E004)

8700017331 (Herasafe S2020, Arnimallee 22, E027)


Safety Operation Instruction (German):

Loading










  • Keine Stichwörter